Remote Physios logo

Assessments

Empowering Recovery through Intelligent Movement Assessment

AI-powered posture, gait, balance, and functional assessments — designed for physiotherapists to track progress and personalize treatment.

50
assessments
5
categories
Camera
only hardware needed

Camera-based modules

Choose an assessment

Each module records movement through the camera and returns a report a physiotherapist can act on.

50 available

  • posture

    Posture Assessment

    A camera-based AI module that identifies postural imbalances, asymmetries, and misalignments to guide accurate correction plans.

    Upload Video

    • AI-driven detection of spinal and shoulder deviations
    • Visual posture mapping with automatic joint calibration
    • Auto-generated physiotherapy report in downloadable PDF
  • gait

    Gait Assessment

    An intelligent walking analysis system that evaluates stride, symmetry, and balance to optimize recovery and mobility training.

    Upload Video

    • Real-time gait and stride analysis through motion tracking
    • Balance and asymmetry detection for rehab progression
    • Instant progress comparison across multiple sessions
  • rom

    Range of Motion (ROM) Assessment

    Measure joint flexibility and movement angles in real time — ideal for recovery monitoring and personalized physiotherapy planning.

    Upload Video

    • Detects joint stiffness and limited range using AI tracking
    • Quantitative progress reports for every exercise routine
    • Helps customize stretching and strengthening programs
  • functional

    I-T-Y Shoulder Hold Assessment

    Evaluate scapular stability, shoulder endurance, and postural control using real-time posture tracking.

    Live Camera

    • Identifies scapular weakness and imbalance across I-T-Y positions
    • Tracks muscle endurance and postural alignment over time
    • Helps tailor shoulder stability and upper-back strengthening programs
  • functional

    Squat Hold Assessment

    Analyze lower-body strength, balance, and mobility through joint angle and posture tracking.

    Live Camera

    • Detects mobility restrictions in hips, knees, and ankles
    • Monitors depth, stability, and weight-shift patterns in real time
    • Supports personalized lower-body strengthening and rehabilitation plans
  • balance

    Single-Leg Stance Assessment

    Time how long the patient balances on each leg, eyes open and closed, with automatic sway and left–right comparison.

    Live Camera

    • Automatic hold timing per leg, eyes open and eyes closed
    • Flags eyes-open holds under 5 s as a fall-risk indicator
    • Measures postural sway and left–right balance asymmetry
  • functional

    30-Second Sit-to-Stand Test

    Counts how many times the patient can stand up from a chair in 30 seconds (or times 5 stands), with age norms and fall-risk banding.

    Live Camera

    • Automatic stand counting from a side-view camera
    • Age- and sex-adjusted norms with a traffic-light result
    • Safety screen, stop button and fall detection built in
  • functional

    Hand Open–Close Speed Test

    Measures how fast, how wide and how steadily each hand opens and closes in 10 seconds, a bradykinesia check after MDS-UPDRS 3.6.

    Live Camera

    • Speed, size, fatigue and rhythm for each hand
    • Left–right comparison and a suggested UPDRS band for the physio
    • Works at any camera distance: sizes are measured in palm lengths
  • functional

    Timed Up and Go (TUG) Test

    Times standing up, walking 3 m, turning, walking back and sitting down, with each phase, gait speed and turning measured for fall-risk screening.

    Live Camera

    • Total time with the five phases split out automatically
    • Gait speed, turning speed and trunk stability during the turn
    • Fall-risk banding with safety screen and helper prompt for high-risk patients
  • balance

    Tandem & Semi-Tandem Stance Test

    Four balance positions held for 10 seconds each — feet together, semi-tandem, tandem and single leg — with sway and foot position measured.

    Live Camera

    • Hold time for each of the four positions, timed automatically
    • Side-to-side sway trace and foot-position accuracy
    • Fall-risk flag when semi-tandem or tandem is under 10 s
  • rom

    Cervical Range of Motion & Forward-Head Posture

    Neck flexion, extension, side-bend and rotation in degrees, plus craniovertebral angle (CVA) for forward head posture and resting head tilt.

    Live Camera

    • All six neck movements measured from the patient’s own neutral, compared with normal ranges
    • Seated craniovertebral angle with forward-head grading
    • Left vs right symmetry, rapid-movement warning and a safety screen for VBI symptoms
  • functional

    Drop-Jump Landing (Knee Valgus Screen)

    Drop jumps on both legs and on each leg, measuring knee valgus (FPPA, knee-to-ankle ratio), hip adduction, trunk lean, landing symmetry and jump height.

    Live Camera

    • Frontal-plane knee angle and knee-to-ankle ratio at the deepest point of landing
    • Left vs right landing timing, contact time and jump height from flight time
    • ACL-risk banding, with knee-pain stop and supervision for high-risk athletes
  • balance

    Y-Balance / Star Excursion Balance Test

    Single-leg reach in anterior, posteromedial and posterolateral directions on a camera floor grid, with composite score, left–right asymmetry, knee valgus and trunk lean.

    Live Camera

    • Reach distance in cm and % of leg length in all three directions, both legs
    • Composite score and anterior asymmetry against injury-risk cut-offs
    • Faults detected automatically: standing heel lifting or foot moving
  • functional

    Trendelenburg Test (Hip Abductor Strength)

    Single-leg stance on each leg measuring pelvic drop and trunk lean against the patient’s own two-leg stance, to screen hip abductor (gluteus medius) weakness.

    Live Camera

    • Pelvic-drop angle on each leg, with the positive sign over 5°
    • Trunk lean over the standing leg flags compensated weakness
    • Left vs right comparison names the weaker hip
  • functional

    Plank / Side-Plank Endurance Test

    Front and side planks held to form failure, with hold time against norms, trunk sag and hip lift, trunk shake and left–right side-plank balance.

    Live Camera

    • Hold time timed automatically until the body line breaks, against healthy norms
    • Trunk sag and hip-lift angles, with a live "lift / lower your hips" cue
    • Side-plank left–right imbalance and fatigue shake, with a knee (modified) option
  • rom

    Sit-and-Reach / Toe-Touch (Hamstring & Lumbar Flexibility)

    Long-sitting toe touch measuring fingertip-to-toe distance in cm, trunk lean, knee-bend compensation and back shape, best of three held reaches.

    Live Camera

    • Fingertip-to-toe distance in cm, live on screen, best of three held reaches
    • Reaches with bent knees or bouncing are caught and not counted
    • Trunk lean and back-shape estimate show whether the reach comes from the hips or the spine
  • rom

    Active Straight-Leg Raise (ASLR) – Hamstring & Hip Flexion

    Lying on the back, straight-leg raise on each side measuring hip flexion with a straight knee, pelvic and other-leg compensation, and left–right difference.

    Live Camera

    • Hip-flexion angle at the top of the raise, live on screen, best of three per leg
    • Bent-knee raises are caught and not counted
    • Other-leg lift and pelvic roll flag lumbo-pelvic compensation; left–right asymmetry
  • functional

    Finger-Tapping / Finger-to-Nose Test (Neurological Upper-Limb)

    Thumb–index tapping for 10 s per hand (speed, size, decrement, rhythm, suggested UPDRS 3.4) and finger-to-nose accuracy with intention-tremor measurement.

    Live Camera

    • Tap rate, size decrement, hesitations and rhythm — with a suggested MDS-UPDRS 3.4 score
    • Finger-to-nose endpoint accuracy in cm and intention tremor size and frequency
    • Left–right comparison for asymmetric slowing
  • functional

    30-Second Arm-Curl Test (Upper-Limb Strength)

    Senior Fitness Test arm curl: full curls in 30 seconds with a light dumbbell, counted from the elbow angle in side view and compared with age and sex norms.

    Live Camera

    • Full curls counted automatically from the elbow angle (under 30° to over 130°)
    • Compared with Senior Fitness Test norms for the patient’s age and sex
    • Partial curls, elbow drift and trunk sway noted; curls per 10 s show fatigue
  • balance

    Romberg & Sharpened Romberg Test

    Feet together and heel-to-toe, eyes open then closed, 30 s each: pelvic sway, eyes-closed vs eyes-open ratio and time to loss of balance.

    Live Camera

    • Side-to-side and front-to-back pelvic sway in cm for each condition
    • Romberg sign from the eyes-closed vs eyes-open comparison
    • Sharpened (tandem) eyes-closed hold time for fall risk; beeps guide eyes-closed stands
  • functional

    Single-Leg Heel-Rise Test (Calf Strength)

    Single-leg heel raises to fatigue on each leg in side view: full-height raises counted, heel-rise height in cm, plantarflexion, fatigue drop and left–right symmetry.

    Live Camera

    • Only full-height raises on one foot are counted, paced by a metronome
    • Heel-rise height in cm, plantarflexion angle and total heel-rise work
    • Fatigue drop and left–right calf symmetry against healthy norms
  • rom

    Overhead Squat / Deep-Squat Screen (Mobility)

    FMS-style deep squat with arms overhead, side and front views: depth, heel lift, trunk vs shin lean, arm drift, knee alignment and a 0–3 grade.

    Live Camera

    • Each squat counted and graded 0–3 automatically, best of three per view
    • Depth, heel lift, trunk vs shin lean and arm drift from the side
    • Knees over the feet and dowel level from the front
  • rom

    Trunk Flexion / Extension ROM (Lumbar Mobility)

    Forward and backward bending side-on and side-bending facing the camera: trunk angles, a lumbar estimate from the back outline, and left–right side-bend symmetry.

    Live Camera

    • Flexion graded on the low-back curve, not the whole-trunk angle that includes the hips
    • Extension and side-bend in degrees, side-bend measured from the pelvis
    • Left–right side-bend symmetry, with a pause for tingling or weakness
  • posture

    Posture-During-ADL / Lifting-Technique Screen

    Lifting a light object floor to waist and back: trunk and knee bend, load distance from the body, twisting and a spine-neutral score, with corrective cues after each lift.

    Live Camera

    • Each lift checked against safe-lift rules: knees > 60°, trunk < 45°, load < 30 cm, no twist
    • Corrective cue after every lift, and the habits to work on in the report
    • Safe-lift and spine-neutral scores for return-to-work and manual-handling training
  • functional

    Visual Smooth-Pursuit Test (Oculomotor Screen)

    The eyes follow a slowly moving dot side to side and up and down, tracked from the iris: pursuit gain, catch-up saccades per cycle, smoothness and direction asymmetry. Research-grade webcam measure.

    Live Camera

    • Pursuit gain (eye speed vs target speed) against the healthy 0.9–1.0 range
    • Catch-up saccades per cycle and a smoothness score for jerky tracking
    • Left–right and up–down asymmetry, with a stop for dizziness or nausea
  • functional

    Saccadic Eye Movement Test (Oculomotor Screen)

    A dot jumps between fixed positions side to side and up and down; iris tracking times each eye jump: latency, accuracy (overshoot / undershoot) and slowed saccades. Research-grade webcam measure.

    Live Camera

    • Saccade latency per direction against the healthy 200–250 ms
    • Accuracy as overshoot or undershoot, with corrective saccades counted
    • Slowed and failed saccades flagged for clinical review, horizontal and vertical
  • functional

    Visual Neglect / Cancellation Task (Camera-Assisted)

    Tap every star on a full-screen page of shapes: omissions on each side and the Centre of Cancellation, with optional camera tracking of head turn, gaze spread and arm reach.

    Live Camera

    • Stars found on each side, with > 20% omissions opposite the lesion flagged as significant neglect
    • Centre of Cancellation, search start and a map of the order stars were found
    • Camera signs: head turned toward the intact side, gaze spread and left–right arm reach
  • functional

    Line Bisection Test (Camera-Monitored)

    Standard-length lines shown one at a time; the patient taps each middle. Deviation in mm and % of the line, timed per line, with optional camera tracking of head turn and gaze.

    Live Camera

    • Deviation from the true middle in mm (card-calibrated screen) and % of each line
    • Consistent rightward deviation > 10% after a right-hemisphere stroke flagged as neglect
    • Per-line time, length and position effects, and whether the gaze reached each end
  • functional

    Praxis / Gesture-Imitation Test

    An animated figure shows six gestures one at a time (wave, salute, stop, brush teeth, comb hair, scissors); Pose and Hands capture each copy, scored pass / fail with error type and a trajectory similarity.

    Live Camera

    • Pass / fail per gesture with the error named: body part as object, spatial, movement or hand shape
    • Communicative vs tool-use gestures compared — the ideomotor apraxia pattern
    • Trajectory similarity to the demonstration and a recorded clip of every attempt
  • functional

    Visual Choice Reaction Time Test

    An arrow points left or right at a random side of the screen; the patient raises that hand (camera-timed) or presses that button. Simple and choice reaction time, accuracy and variability, after practice trials.

    Live Camera

    • Simple and choice reaction time against healthy ranges, with decision time between them
    • Choice accuracy, misses, jump starts and trial-to-trial variability
    • Hand-raise timing by camera, or a button version for patients who can’t lift both arms
  • functional

    Mirror-Movement / Bilateral Symmetry Task

    Both arms raised forward together, then each hand opening and closing while the other rests: a left–right symmetry index from the arm paths, side-by-side hand speed and range, and mirror movements in the resting hand.

    Live Camera

    • Symmetry index (cosine of left/right arm paths) with height ratio and timing lag
    • Hand open–close rate and range compared side to side, naming the weaker side
    • Mirror movements in the resting hand flagged separately, graded mild or marked
  • functional

    Body-Schema / Self-Touch Accuracy Test (Eyes Closed)

    With eyes closed (checked by Face Mesh), the patient touches the nose, opposite ear and opposite shoulder; fingertip-to-target error in cm, overshoot or undershoot, and tremor on approach.

    Live Camera

    • Endpoint error in cm for each target and hand, against the healthy ≈ 2 cm
    • Persistent overshoot / undershoot and intention tremor — the cerebellar dysmetria pattern
    • Eyes-closed vs eyes-open accuracy, with closed eyes verified before every touch
  • functional

    Facial Symmetry Assessment (Resting + Voluntary) — House-Brackmann Surrogate

    Face Mesh symmetry of eyebrows, eyes, mouth corners and nasolabial region at rest and in eight expressions, with incomplete eye closure, synkinesis and a House-Brackmann surrogate grade.

    Live Camera

    • Resting and voluntary symmetry indices (left vs right), healthy > 0.95
    • Weaker side, mouth-corner droop, incomplete eye closure and possible synkinesis
    • House-Brackmann surrogate grade I–VI as decision-support for the clinician
  • functional

    Eye Closure Symmetry Test (CN VII / Lagophthalmos Screen)

    Face Mesh eyelid gap in mm for each eye, open and at gentle and forced closure: full closure, lagophthalmos (> 2 mm) with a corneal-protection referral flag, and left–right lid symmetry.

    Live Camera

    • Lid gap at maximal closure in mm for each eye, against healthy full closure (< 1 mm)
    • Persistent gap > 2 mm flagged as lagophthalmos with a corneal-protection referral
    • Left–right closing symmetry and lid lag, gentle vs forced closure
  • functional

    Smile / Lip-Retraction Symmetry Test

    Mouth corners at rest and during gentle and full smiles: each corner’s rise and outward pull in mm, the left–right difference, lip-retraction symmetry and the % deficit of the weaker side.

    Live Camera

    • Mouth-corner elevation on each side in mm, healthy within ≈ 2 mm of each other
    • Lip-retraction symmetry index and the weaker corner’s % deficit
    • Repeated smiles show persistent asymmetry — repeat over time to track recovery
  • functional

    Lip Pucker / Lip Closure Test

    Pucker and gentle lip closure: how much the mouth narrows and pushes forward, whether both sides pull in alike, fading while held, and whether the lips seal along their length.

    Live Camera

    • Pucker strength (mouth narrowing) and forward push, with fading over a 5-second hold
    • Left–right pucker symmetry and pull to one side — facial-nerve weakness
    • Lip-seal completeness at the right, centre and left of the mouth
  • functional

    Forehead Wrinkle / Brow Elevation Test

    Raise both eyebrows and smile: brow lift and forehead wrinkling on each side compared with the lower face, to tell a forehead-sparing (upper-motor-neuron, e.g. stroke) palsy from a lower-motor-neuron (e.g. Bell’s) palsy.

    Live Camera

    • Brow lift on each side in mm and a left–right symmetry index
    • Forehead wrinkling on each side compared with rest
    • Forehead vs lower-face weakness — UMN (forehead spared) vs LMN pattern, as a clinical adjunct
  • functional

    Tongue Protrusion / Deviation Test (CN XII)

    Stick the tongue straight out: how far the tip sits from the facial midline in mm, for hypoglossal weakness after stroke, ALS or radiation. Research-grade — tongue tracking needs good front light.

    Live Camera

    • Tongue-tip offset from the facial midline in mm, on three protrusions
    • Side of deviation — over 5 mm suggests same-side hypoglossal or opposite-side cortical weakness
    • Reach past the lip and steadiness of the hold, with a lighting / colour check
  • functional

    Thumb Opposition / Kapandji Score

    Reach the thumb across the palm toward the little finger: the Kapandji 0–10 score from the furthest point the thumb tip touches, for stroke hand recovery, median nerve injury, CTS, tendon repair or rheumatoid hand.

    Live Camera

    • Kapandji score 0–10 for each hand — healthy adults reach 10, 6 or below is a functional deficit
    • Which point along fingers 2–5 and the palm the thumb reaches, and how close it gets to the palmar crease
    • Flags fingers bending to meet the thumb, and compares left and right hands
  • functional

    Finger-Individuation Test

    Hand flat on a table, lift each finger in turn while keeping the others down: how much the other fingers move with it (involuntary co-activation %), for stroke hand recovery, focal hand dystonia or tendon repair.

    Live Camera

    • Involuntary co-activation % and individuation index for each hand — healthy ≤ 10%, 40–80% after stroke
    • Finger-by-finger matrix of which neighbours move with each lifted finger
    • MCP lift angle of each finger, and fingers that cannot lift on their own
  • functional

    Pincer Grip Test (Tip-to-Tip, Lateral, Tripod)

    Form and hold tip-to-tip, lateral and tripod pinches on a beep: time to grip, hold duration, contact gap and grip form for each hand, with left–right symmetry — for hand recovery after stroke, CTS or thumb OA.

    Live Camera

    • Valid and successful attempts, time to grip and hold duration for each grip and hand
    • Tip-to-tip contact gap (healthy < 5 mm) and lateral-pinch thumb angle at the index PIP
    • Left vs right symmetry of each grip
  • functional

    Wrist ROM Assessment (Flex/Ext, Radial/Ulnar Deviation, Pronation/Supination)

    Elbow on a table, forearm upright: wrist flexion, extension, radial and ulnar deviation, and forearm pronation and supination in degrees from hand and forearm tracking, compared with normal and between wrists — after Colles fracture, CTS surgery, RA or post-stroke contracture.

    Live Camera

    • Six wrist and forearm ranges in degrees and as % of normal (flexion 80°, extension 70°, radial 20°, ulnar 30°, pronation/supination 80°)
    • Left vs right difference for every movement
    • Flags the forearm or upper arm moving to make up range
  • functional

    Box-and-Blocks Virtual Test

    Pinch virtual blocks and carry them over a partition from one box to the other with hand tracking: blocks moved in 60 seconds per hand, for gross manual dexterity after stroke, MS or hand injury. Adapted measure — not interchangeable with the physical test.

    Live Camera

    • Blocks moved in 60 s with each hand, after 15 s of practice
    • Non-dominant vs dominant ratio, drops and blocks carried through the partition
    • Optional calibration against the patient’s physical Box and Block score
  • functional

    Finger-Sequencing Test (Thumb-to-Finger Tapping)

    Touch the thumb to the index, middle, ring and little fingers in order for 10 seconds: correct sequences, sequence errors and rhythm regularity for each hand — fine-motor coordination in Parkinson’s, cerebellar disorders and stroke recovery.

    Live Camera

    • Correct sequences in 10 s for each hand — healthy adults complete 4 or more
    • Sequence errors (wrong or skipped fingers) and pauses
    • Rhythm regularity between taps — irregularity suggests cerebellar or basal-ganglia dysfunction
  • functional

    Pronator Drift Test

    Arms held forward at shoulder height, palms up, eyes closed (checked from the face) for 20 seconds: downward drift, palm turning down, inward drift and elbow bending of each arm — a screen for subtle upper-motor-neuron weakness after early stroke, MS or a brain lesion.

    Live Camera

    • Downward drift (cm), pronation (°), inward drift (cm) and elbow flexion (°) for each arm
    • One-sided pronation with downward drift flagged as a positive pronator drift
    • Eye closure confirmed from the face, so vision can’t mask a drift
  • functional

    Dysdiadochokinesia (Rapid Alternating Movements)

    Turn the hand palm-up and palm-down as fast as possible for 10 seconds: cycles, speed, rhythm and turn-size consistency for each hand, with left–right comparison — for cerebellar ataxia, MS and cerebellar stroke.

    Live Camera

    • Cycles in a 10-second trial and frequency for each hand — healthy ≥ 4 turns per second
    • Rhythm regularity and turn-size consistency (decomposition)
    • Left vs right speed asymmetry
  • functional

    Heel-Knee-Shin Test (Lower-Limb Cerebellar)

    Lying on the back, slide each heel from the opposite knee down the shin: how far the heel strays from the shin line (mm), tremor on the slide and on approach, and how smooth the slide is — for cerebellar ataxia, MS and cerebellar or brainstem stroke.

    Live Camera

    • Heel deviation from the shin line in mm, scaled to the patient’s height
    • Tremor during the slide and as the heel approaches the knee, with its frequency
    • Smoothness (movement units) — a broken-up slide shows decomposition
  • functional

    Respiratory Rate via Shoulder/Chest Motion

    Sitting quietly for 60 seconds: breaths per minute from shoulder rise and upper-chest movement, against the adult (12–20) or age-based child range — for cardiac rehab, COPD home monitoring, after chest surgery and dysfunctional-breathing screening.

    Live Camera

    • Respiratory rate in breaths per minute over 60 s, with signal quality
    • Normal range by age from the profile (adult 12–20; children by AHA PALS ranges)
    • Breath-to-breath regularity and long pauses; resting or post-exercise recovery recorded
  • functional

    Countermovement Jump (CMJ) — Vertical Jump Height

    Quick dip and jump straight up: jump height from flight time, hip rise and dip in cm, landing knee valgus and, with single-leg jumps, the Limb Symmetry Index — for lower-limb power, ACL rehab and return-to-sport screening.

    Live Camera

    • Best and mean jump height from flight time, against young-adult norms by sex
    • Landing knee valgus (FPPA) as a concurrent ACL screen
    • Single-leg jumps for the Limb Symmetry Index (> 90% for return to sport)
  • functional

    Single-Leg Hop for Distance (ACL Return-to-Sport)

    Supervised single-leg hops toward the camera, three per leg: hop distance, Limb Symmetry Index, landing knee valgus, trunk lean and whether the landing is held — for ACL reconstruction rehab and return-to-sport screening.

    Live Camera

    • Hop distance per leg (tape measure or camera estimate) and the Limb Symmetry Index — target ≥ 90%
    • Landing knee valgus and trunk lean on each hop
    • Whether each landing is held without a touch-down, extra hop or loss of balance

Questions about the assessments

A camera-enabled device with a clear view of the whole body. The system calibrates itself and finds the joint points on its own.