Empowering Recovery through Intelligent Movement Assessment
AI-powered posture, gait, balance, and functional assessments — designed for physiotherapists to track progress and personalize treatment.
50
assessments
5
categories
Camera
only hardware needed
Camera-based modules
Choose an assessment
Each module records movement through the camera and returns a report a physiotherapist can act on.
50 available
posture
Posture Assessment
A camera-based AI module that identifies postural imbalances, asymmetries, and misalignments to guide accurate correction plans.
Upload Video
AI-driven detection of spinal and shoulder deviations
Visual posture mapping with automatic joint calibration
Auto-generated physiotherapy report in downloadable PDF
gait
Gait Assessment
An intelligent walking analysis system that evaluates stride, symmetry, and balance to optimize recovery and mobility training.
Upload Video
Real-time gait and stride analysis through motion tracking
Balance and asymmetry detection for rehab progression
Instant progress comparison across multiple sessions
rom
Range of Motion (ROM) Assessment
Measure joint flexibility and movement angles in real time — ideal for recovery monitoring and personalized physiotherapy planning.
Upload Video
Detects joint stiffness and limited range using AI tracking
Quantitative progress reports for every exercise routine
Helps customize stretching and strengthening programs
functional
I-T-Y Shoulder Hold Assessment
Evaluate scapular stability, shoulder endurance, and postural control using real-time posture tracking.
Live Camera
Identifies scapular weakness and imbalance across I-T-Y positions
Tracks muscle endurance and postural alignment over time
Helps tailor shoulder stability and upper-back strengthening programs
functional
Squat Hold Assessment
Analyze lower-body strength, balance, and mobility through joint angle and posture tracking.
Live Camera
Detects mobility restrictions in hips, knees, and ankles
Monitors depth, stability, and weight-shift patterns in real time
Supports personalized lower-body strengthening and rehabilitation plans
balance
Single-Leg Stance Assessment
Time how long the patient balances on each leg, eyes open and closed, with automatic sway and left–right comparison.
Live Camera
Automatic hold timing per leg, eyes open and eyes closed
Flags eyes-open holds under 5 s as a fall-risk indicator
Measures postural sway and left–right balance asymmetry
functional
30-Second Sit-to-Stand Test
Counts how many times the patient can stand up from a chair in 30 seconds (or times 5 stands), with age norms and fall-risk banding.
Live Camera
Automatic stand counting from a side-view camera
Age- and sex-adjusted norms with a traffic-light result
Safety screen, stop button and fall detection built in
functional
Hand Open–Close Speed Test
Measures how fast, how wide and how steadily each hand opens and closes in 10 seconds, a bradykinesia check after MDS-UPDRS 3.6.
Live Camera
Speed, size, fatigue and rhythm for each hand
Left–right comparison and a suggested UPDRS band for the physio
Works at any camera distance: sizes are measured in palm lengths
functional
Timed Up and Go (TUG) Test
Times standing up, walking 3 m, turning, walking back and sitting down, with each phase, gait speed and turning measured for fall-risk screening.
Live Camera
Total time with the five phases split out automatically
Gait speed, turning speed and trunk stability during the turn
Fall-risk banding with safety screen and helper prompt for high-risk patients
balance
Tandem & Semi-Tandem Stance Test
Four balance positions held for 10 seconds each — feet together, semi-tandem, tandem and single leg — with sway and foot position measured.
Live Camera
Hold time for each of the four positions, timed automatically
Side-to-side sway trace and foot-position accuracy
Fall-risk flag when semi-tandem or tandem is under 10 s
rom
Cervical Range of Motion & Forward-Head Posture
Neck flexion, extension, side-bend and rotation in degrees, plus craniovertebral angle (CVA) for forward head posture and resting head tilt.
Live Camera
All six neck movements measured from the patient’s own neutral, compared with normal ranges
Seated craniovertebral angle with forward-head grading
Left vs right symmetry, rapid-movement warning and a safety screen for VBI symptoms
functional
Drop-Jump Landing (Knee Valgus Screen)
Drop jumps on both legs and on each leg, measuring knee valgus (FPPA, knee-to-ankle ratio), hip adduction, trunk lean, landing symmetry and jump height.
Live Camera
Frontal-plane knee angle and knee-to-ankle ratio at the deepest point of landing
Left vs right landing timing, contact time and jump height from flight time
ACL-risk banding, with knee-pain stop and supervision for high-risk athletes
balance
Y-Balance / Star Excursion Balance Test
Single-leg reach in anterior, posteromedial and posterolateral directions on a camera floor grid, with composite score, left–right asymmetry, knee valgus and trunk lean.
Live Camera
Reach distance in cm and % of leg length in all three directions, both legs
Composite score and anterior asymmetry against injury-risk cut-offs
Faults detected automatically: standing heel lifting or foot moving
functional
Trendelenburg Test (Hip Abductor Strength)
Single-leg stance on each leg measuring pelvic drop and trunk lean against the patient’s own two-leg stance, to screen hip abductor (gluteus medius) weakness.
Live Camera
Pelvic-drop angle on each leg, with the positive sign over 5°
Trunk lean over the standing leg flags compensated weakness
Left vs right comparison names the weaker hip
functional
Plank / Side-Plank Endurance Test
Front and side planks held to form failure, with hold time against norms, trunk sag and hip lift, trunk shake and left–right side-plank balance.
Live Camera
Hold time timed automatically until the body line breaks, against healthy norms
Trunk sag and hip-lift angles, with a live "lift / lower your hips" cue
Side-plank left–right imbalance and fatigue shake, with a knee (modified) option
Long-sitting toe touch measuring fingertip-to-toe distance in cm, trunk lean, knee-bend compensation and back shape, best of three held reaches.
Live Camera
Fingertip-to-toe distance in cm, live on screen, best of three held reaches
Reaches with bent knees or bouncing are caught and not counted
Trunk lean and back-shape estimate show whether the reach comes from the hips or the spine
rom
Active Straight-Leg Raise (ASLR) – Hamstring & Hip Flexion
Lying on the back, straight-leg raise on each side measuring hip flexion with a straight knee, pelvic and other-leg compensation, and left–right difference.
Live Camera
Hip-flexion angle at the top of the raise, live on screen, best of three per leg
Bent-knee raises are caught and not counted
Other-leg lift and pelvic roll flag lumbo-pelvic compensation; left–right asymmetry
functional
Finger-Tapping / Finger-to-Nose Test (Neurological Upper-Limb)
Thumb–index tapping for 10 s per hand (speed, size, decrement, rhythm, suggested UPDRS 3.4) and finger-to-nose accuracy with intention-tremor measurement.
Live Camera
Tap rate, size decrement, hesitations and rhythm — with a suggested MDS-UPDRS 3.4 score
Finger-to-nose endpoint accuracy in cm and intention tremor size and frequency
Left–right comparison for asymmetric slowing
functional
30-Second Arm-Curl Test (Upper-Limb Strength)
Senior Fitness Test arm curl: full curls in 30 seconds with a light dumbbell, counted from the elbow angle in side view and compared with age and sex norms.
Live Camera
Full curls counted automatically from the elbow angle (under 30° to over 130°)
Compared with Senior Fitness Test norms for the patient’s age and sex
Partial curls, elbow drift and trunk sway noted; curls per 10 s show fatigue
balance
Romberg & Sharpened Romberg Test
Feet together and heel-to-toe, eyes open then closed, 30 s each: pelvic sway, eyes-closed vs eyes-open ratio and time to loss of balance.
Live Camera
Side-to-side and front-to-back pelvic sway in cm for each condition
Romberg sign from the eyes-closed vs eyes-open comparison
Sharpened (tandem) eyes-closed hold time for fall risk; beeps guide eyes-closed stands
functional
Single-Leg Heel-Rise Test (Calf Strength)
Single-leg heel raises to fatigue on each leg in side view: full-height raises counted, heel-rise height in cm, plantarflexion, fatigue drop and left–right symmetry.
Live Camera
Only full-height raises on one foot are counted, paced by a metronome
Heel-rise height in cm, plantarflexion angle and total heel-rise work
Fatigue drop and left–right calf symmetry against healthy norms
rom
Overhead Squat / Deep-Squat Screen (Mobility)
FMS-style deep squat with arms overhead, side and front views: depth, heel lift, trunk vs shin lean, arm drift, knee alignment and a 0–3 grade.
Live Camera
Each squat counted and graded 0–3 automatically, best of three per view
Depth, heel lift, trunk vs shin lean and arm drift from the side
Knees over the feet and dowel level from the front
rom
Trunk Flexion / Extension ROM (Lumbar Mobility)
Forward and backward bending side-on and side-bending facing the camera: trunk angles, a lumbar estimate from the back outline, and left–right side-bend symmetry.
Live Camera
Flexion graded on the low-back curve, not the whole-trunk angle that includes the hips
Extension and side-bend in degrees, side-bend measured from the pelvis
Left–right side-bend symmetry, with a pause for tingling or weakness
posture
Posture-During-ADL / Lifting-Technique Screen
Lifting a light object floor to waist and back: trunk and knee bend, load distance from the body, twisting and a spine-neutral score, with corrective cues after each lift.
Live Camera
Each lift checked against safe-lift rules: knees > 60°, trunk < 45°, load < 30 cm, no twist
Corrective cue after every lift, and the habits to work on in the report
Safe-lift and spine-neutral scores for return-to-work and manual-handling training
functional
Visual Smooth-Pursuit Test (Oculomotor Screen)
The eyes follow a slowly moving dot side to side and up and down, tracked from the iris: pursuit gain, catch-up saccades per cycle, smoothness and direction asymmetry. Research-grade webcam measure.
Live Camera
Pursuit gain (eye speed vs target speed) against the healthy 0.9–1.0 range
Catch-up saccades per cycle and a smoothness score for jerky tracking
Left–right and up–down asymmetry, with a stop for dizziness or nausea
functional
Saccadic Eye Movement Test (Oculomotor Screen)
A dot jumps between fixed positions side to side and up and down; iris tracking times each eye jump: latency, accuracy (overshoot / undershoot) and slowed saccades. Research-grade webcam measure.
Live Camera
Saccade latency per direction against the healthy 200–250 ms
Accuracy as overshoot or undershoot, with corrective saccades counted
Slowed and failed saccades flagged for clinical review, horizontal and vertical
Tap every star on a full-screen page of shapes: omissions on each side and the Centre of Cancellation, with optional camera tracking of head turn, gaze spread and arm reach.
Live Camera
Stars found on each side, with > 20% omissions opposite the lesion flagged as significant neglect
Centre of Cancellation, search start and a map of the order stars were found
Camera signs: head turned toward the intact side, gaze spread and left–right arm reach
functional
Line Bisection Test (Camera-Monitored)
Standard-length lines shown one at a time; the patient taps each middle. Deviation in mm and % of the line, timed per line, with optional camera tracking of head turn and gaze.
Live Camera
Deviation from the true middle in mm (card-calibrated screen) and % of each line
Consistent rightward deviation > 10% after a right-hemisphere stroke flagged as neglect
Per-line time, length and position effects, and whether the gaze reached each end
functional
Praxis / Gesture-Imitation Test
An animated figure shows six gestures one at a time (wave, salute, stop, brush teeth, comb hair, scissors); Pose and Hands capture each copy, scored pass / fail with error type and a trajectory similarity.
Live Camera
Pass / fail per gesture with the error named: body part as object, spatial, movement or hand shape
Communicative vs tool-use gestures compared — the ideomotor apraxia pattern
Trajectory similarity to the demonstration and a recorded clip of every attempt
functional
Visual Choice Reaction Time Test
An arrow points left or right at a random side of the screen; the patient raises that hand (camera-timed) or presses that button. Simple and choice reaction time, accuracy and variability, after practice trials.
Live Camera
Simple and choice reaction time against healthy ranges, with decision time between them
Choice accuracy, misses, jump starts and trial-to-trial variability
Hand-raise timing by camera, or a button version for patients who can’t lift both arms
functional
Mirror-Movement / Bilateral Symmetry Task
Both arms raised forward together, then each hand opening and closing while the other rests: a left–right symmetry index from the arm paths, side-by-side hand speed and range, and mirror movements in the resting hand.
Live Camera
Symmetry index (cosine of left/right arm paths) with height ratio and timing lag
Hand open–close rate and range compared side to side, naming the weaker side
Mirror movements in the resting hand flagged separately, graded mild or marked
functional
Body-Schema / Self-Touch Accuracy Test (Eyes Closed)
With eyes closed (checked by Face Mesh), the patient touches the nose, opposite ear and opposite shoulder; fingertip-to-target error in cm, overshoot or undershoot, and tremor on approach.
Live Camera
Endpoint error in cm for each target and hand, against the healthy ≈ 2 cm
Persistent overshoot / undershoot and intention tremor — the cerebellar dysmetria pattern
Eyes-closed vs eyes-open accuracy, with closed eyes verified before every touch
Face Mesh symmetry of eyebrows, eyes, mouth corners and nasolabial region at rest and in eight expressions, with incomplete eye closure, synkinesis and a House-Brackmann surrogate grade.
Live Camera
Resting and voluntary symmetry indices (left vs right), healthy > 0.95
Weaker side, mouth-corner droop, incomplete eye closure and possible synkinesis
House-Brackmann surrogate grade I–VI as decision-support for the clinician
functional
Eye Closure Symmetry Test (CN VII / Lagophthalmos Screen)
Face Mesh eyelid gap in mm for each eye, open and at gentle and forced closure: full closure, lagophthalmos (> 2 mm) with a corneal-protection referral flag, and left–right lid symmetry.
Live Camera
Lid gap at maximal closure in mm for each eye, against healthy full closure (< 1 mm)
Persistent gap > 2 mm flagged as lagophthalmos with a corneal-protection referral
Left–right closing symmetry and lid lag, gentle vs forced closure
functional
Smile / Lip-Retraction Symmetry Test
Mouth corners at rest and during gentle and full smiles: each corner’s rise and outward pull in mm, the left–right difference, lip-retraction symmetry and the % deficit of the weaker side.
Live Camera
Mouth-corner elevation on each side in mm, healthy within ≈ 2 mm of each other
Lip-retraction symmetry index and the weaker corner’s % deficit
Repeated smiles show persistent asymmetry — repeat over time to track recovery
functional
Lip Pucker / Lip Closure Test
Pucker and gentle lip closure: how much the mouth narrows and pushes forward, whether both sides pull in alike, fading while held, and whether the lips seal along their length.
Live Camera
Pucker strength (mouth narrowing) and forward push, with fading over a 5-second hold
Left–right pucker symmetry and pull to one side — facial-nerve weakness
Lip-seal completeness at the right, centre and left of the mouth
functional
Forehead Wrinkle / Brow Elevation Test
Raise both eyebrows and smile: brow lift and forehead wrinkling on each side compared with the lower face, to tell a forehead-sparing (upper-motor-neuron, e.g. stroke) palsy from a lower-motor-neuron (e.g. Bell’s) palsy.
Live Camera
Brow lift on each side in mm and a left–right symmetry index
Forehead wrinkling on each side compared with rest
Forehead vs lower-face weakness — UMN (forehead spared) vs LMN pattern, as a clinical adjunct
functional
Tongue Protrusion / Deviation Test (CN XII)
Stick the tongue straight out: how far the tip sits from the facial midline in mm, for hypoglossal weakness after stroke, ALS or radiation. Research-grade — tongue tracking needs good front light.
Live Camera
Tongue-tip offset from the facial midline in mm, on three protrusions
Side of deviation — over 5 mm suggests same-side hypoglossal or opposite-side cortical weakness
Reach past the lip and steadiness of the hold, with a lighting / colour check
functional
Thumb Opposition / Kapandji Score
Reach the thumb across the palm toward the little finger: the Kapandji 0–10 score from the furthest point the thumb tip touches, for stroke hand recovery, median nerve injury, CTS, tendon repair or rheumatoid hand.
Live Camera
Kapandji score 0–10 for each hand — healthy adults reach 10, 6 or below is a functional deficit
Which point along fingers 2–5 and the palm the thumb reaches, and how close it gets to the palmar crease
Flags fingers bending to meet the thumb, and compares left and right hands
functional
Finger-Individuation Test
Hand flat on a table, lift each finger in turn while keeping the others down: how much the other fingers move with it (involuntary co-activation %), for stroke hand recovery, focal hand dystonia or tendon repair.
Live Camera
Involuntary co-activation % and individuation index for each hand — healthy ≤ 10%, 40–80% after stroke
Finger-by-finger matrix of which neighbours move with each lifted finger
MCP lift angle of each finger, and fingers that cannot lift on their own
functional
Pincer Grip Test (Tip-to-Tip, Lateral, Tripod)
Form and hold tip-to-tip, lateral and tripod pinches on a beep: time to grip, hold duration, contact gap and grip form for each hand, with left–right symmetry — for hand recovery after stroke, CTS or thumb OA.
Live Camera
Valid and successful attempts, time to grip and hold duration for each grip and hand
Tip-to-tip contact gap (healthy < 5 mm) and lateral-pinch thumb angle at the index PIP
Left vs right symmetry of each grip
functional
Wrist ROM Assessment (Flex/Ext, Radial/Ulnar Deviation, Pronation/Supination)
Elbow on a table, forearm upright: wrist flexion, extension, radial and ulnar deviation, and forearm pronation and supination in degrees from hand and forearm tracking, compared with normal and between wrists — after Colles fracture, CTS surgery, RA or post-stroke contracture.
Live Camera
Six wrist and forearm ranges in degrees and as % of normal (flexion 80°, extension 70°, radial 20°, ulnar 30°, pronation/supination 80°)
Left vs right difference for every movement
Flags the forearm or upper arm moving to make up range
functional
Box-and-Blocks Virtual Test
Pinch virtual blocks and carry them over a partition from one box to the other with hand tracking: blocks moved in 60 seconds per hand, for gross manual dexterity after stroke, MS or hand injury. Adapted measure — not interchangeable with the physical test.
Live Camera
Blocks moved in 60 s with each hand, after 15 s of practice
Non-dominant vs dominant ratio, drops and blocks carried through the partition
Optional calibration against the patient’s physical Box and Block score
functional
Finger-Sequencing Test (Thumb-to-Finger Tapping)
Touch the thumb to the index, middle, ring and little fingers in order for 10 seconds: correct sequences, sequence errors and rhythm regularity for each hand — fine-motor coordination in Parkinson’s, cerebellar disorders and stroke recovery.
Live Camera
Correct sequences in 10 s for each hand — healthy adults complete 4 or more
Sequence errors (wrong or skipped fingers) and pauses
Rhythm regularity between taps — irregularity suggests cerebellar or basal-ganglia dysfunction
functional
Pronator Drift Test
Arms held forward at shoulder height, palms up, eyes closed (checked from the face) for 20 seconds: downward drift, palm turning down, inward drift and elbow bending of each arm — a screen for subtle upper-motor-neuron weakness after early stroke, MS or a brain lesion.
Live Camera
Downward drift (cm), pronation (°), inward drift (cm) and elbow flexion (°) for each arm
One-sided pronation with downward drift flagged as a positive pronator drift
Eye closure confirmed from the face, so vision can’t mask a drift
functional
Dysdiadochokinesia (Rapid Alternating Movements)
Turn the hand palm-up and palm-down as fast as possible for 10 seconds: cycles, speed, rhythm and turn-size consistency for each hand, with left–right comparison — for cerebellar ataxia, MS and cerebellar stroke.
Live Camera
Cycles in a 10-second trial and frequency for each hand — healthy ≥ 4 turns per second
Rhythm regularity and turn-size consistency (decomposition)
Left vs right speed asymmetry
functional
Heel-Knee-Shin Test (Lower-Limb Cerebellar)
Lying on the back, slide each heel from the opposite knee down the shin: how far the heel strays from the shin line (mm), tremor on the slide and on approach, and how smooth the slide is — for cerebellar ataxia, MS and cerebellar or brainstem stroke.
Live Camera
Heel deviation from the shin line in mm, scaled to the patient’s height
Tremor during the slide and as the heel approaches the knee, with its frequency
Smoothness (movement units) — a broken-up slide shows decomposition
functional
Respiratory Rate via Shoulder/Chest Motion
Sitting quietly for 60 seconds: breaths per minute from shoulder rise and upper-chest movement, against the adult (12–20) or age-based child range — for cardiac rehab, COPD home monitoring, after chest surgery and dysfunctional-breathing screening.
Live Camera
Respiratory rate in breaths per minute over 60 s, with signal quality
Normal range by age from the profile (adult 12–20; children by AHA PALS ranges)
Breath-to-breath regularity and long pauses; resting or post-exercise recovery recorded
functional
Countermovement Jump (CMJ) — Vertical Jump Height
Quick dip and jump straight up: jump height from flight time, hip rise and dip in cm, landing knee valgus and, with single-leg jumps, the Limb Symmetry Index — for lower-limb power, ACL rehab and return-to-sport screening.
Live Camera
Best and mean jump height from flight time, against young-adult norms by sex
Landing knee valgus (FPPA) as a concurrent ACL screen
Single-leg jumps for the Limb Symmetry Index (> 90% for return to sport)
functional
Single-Leg Hop for Distance (ACL Return-to-Sport)
Supervised single-leg hops toward the camera, three per leg: hop distance, Limb Symmetry Index, landing knee valgus, trunk lean and whether the landing is held — for ACL reconstruction rehab and return-to-sport screening.
Live Camera
Hop distance per leg (tape measure or camera estimate) and the Limb Symmetry Index — target ≥ 90%
Landing knee valgus and trunk lean on each hop
Whether each landing is held without a touch-down, extra hop or loss of balance
Questions about the assessments
A camera-enabled device with a clear view of the whole body. The system calibrates itself and finds the joint points on its own.